Pitco fryer manual




















The times will be automatically displayed in sequence, the display will return to the run mode. The BOIL mode will be automatical. Be sure to clean the front panel and behind the door. The fryer should be completely drained of shortening. Fill the fry tank with water to above the minimum and below the maximum level lines.

Make sure the machine is operated correctly and that the Computer or Digital Display when installed is programmed accordingly. Hi-Limit reset Press Hi-Limit reset button.

Mounted on. Check for continuity across the terminations when the wires are disconnected. Light the Pilot and measure the DC voltage. The voltage should be mv. If the measured voltage is less than specified, the part sh.

If the Probe is not at fault the computer may be suspect. Defective HSI. Defective HSI module. Burners come ON but shut down after a few seconds. Defective Burner. Incorrect Gas or Air pressure.

Burners try to ignite but Blower does NOT come on. Defective Blower Relay. Defective Blower. Machine will not run: No lights on the front panel Power to machine Where applicable. Machine will not run: Front panel lights are ON.

Call Authorized Service Company Shortening is leaking from fry tank Call Authorized Service Company Power to machine Check main power to the machine Circuit breaker Check filter circuit breaker on side of filter handle Motor overheat trip Remove cap on the left side at the rear of filter and push red button Shortening return quick disconnect Fitting should be tight and clean Pick up tube Steel nut should be tight on the filter Pick up screen inside tube should be clear Fitting at top of tube should be tight Paper installation Paper should be installed per directions in the manual Pick up screen Check the small screen in the end of the pick up tube Inside the large steel nut.

Main circuit breaker is turned off A. Fryer fuse is blown B. Check and Replace as needed C. Transformer C. Allowr the oil to cool, the Hi Limit will reset itself.

Computer A. Switch circuit breaker OFF and ON again to try to reset computer, if this does not remedy the problem, replace computer.

I leat Demand Relay A. Check Heat Demand Relay. F2 Fuse may be blown B. Check and replace as needed. Blower D. Pressure Switch E. Gas Valve F. Tripped or defective Hi Limit H. Allow the oil to cool, the I li Limit will reset itself. Check and replace is needed. No Spark heard, blower IS running A. Heat Demand Relay A. Check and replace where needed. Ignition Control Module C. F2 ftise blown B. Blower C. Ignition Control Module B. Bad Pressure Switch D.

Tripped or defective Hi limit E. Flame Sensor B. Gas Valve Computer controls left side of split vat only A. Wiring harnesses attached in wrong order A.